Tempest 100
|
Tempest 100 is a compact, lightweight emissions monitor, capable of multi-gas
measurements. With O2, CO, CO2 (calculated) and NO as standard, optional
sensors that can be simultaneously fitted include NO2, SO2 and H2S. Its
integral printer and data logging facility give flexibility to the user
whilst retaining ease of use. Temperature and pressure sensors, and 4-20mA
and RS232 outputs are supplied as standard.
This compact instrument
may be used as an inexpensive back-up to more costly fixed systems, or as a
standalone emissions monitor in its own right. Its sophisticated array of
standard and optional features, combined with its light weight (1.3 Kg), make this a
truly portable and easy to use instrument, be it monitoring on power
stations, industrial boilers, paper plants, or wherever quick emissions
measurements are required
|
|
Specifications
Display (backlit LCD) 4 lines, 20 characters
wide
Personalised header 2 lines, 16 characters
each line
Ambient operating temp 0ºC to 40ºC : 32ºF to
104ºF
Battery recharge to full 2 hours
Charger input voltage 115V or 230V: 50/60 Hz
AC
Fuels Natural gas, light oil, propane, heavy
oil, coal, coke
Dimensions (mm/inches) 280mm (w) x 120 (d) x
112 (h): 11 inches
x 4.8 x 4.5
Weight: 1.3Kg 3lbs (no case)
|
|
Sensors Specifications
|
Sensors
|
Range
|
Resolution
|
Accuracy
|
|
O2
|
0 to 25%
|
0.1%
|
+0.3%
|
|
CO
|
0 to 10,000 ppm
|
1 ppm
|
>100 ppm; +5%
|
|
NO
|
0 to 1,000 ppm
|
1 ppm
|
>100 ppm; +5%
|
* Optional
|
|
Probe
Specifications
Construction Pistol grip with stainless
steel shaft
Insertion length 300mm : 12 inches
Hose length 2500mm : 98 inches
K-type thermocouple Accuracy +/-1ºC
Max temperature
Standard probe 800ºC
High temp probe 1,100ºC
|
|
Tempest 100 - Configurations
|
|
c/w O2, CO & NO sensors, calculated CO2 & ratio
|
99F21001
|
|
c/w O2, CO & NO sensors, calculated CO2, ratio & NO2
|
99F21002
|
|
c/w O2, CO & NO sensors, calculated CO2, ratio & SO2
|
99F21003
|
|
c/w O2, CO & NO sensors, calculated CO2, ratio, NO2 & SO2
|
99F21004
|
|
Options on Tempest 100 New
Builds
|
|
Hydrogen Sulfide (H2S)
|
OPT21001
|
|
Hydrogen Chloride (HCI)
|
OPT21002
|
|
Calculation of Stack Losses
|
OPT20050
|
|
Tempest 100 - Common Options
|
|
Carbon Monoxide (CO) Sensor, 0% to 10%
|
OPT20039
|
|
User-defined Fuel (non-standard)
|
OPT20041
|
|
3' Probe
|
PRB20062
|
|
Probe High Temperature (max 2000F)
|
PRB20061
|
|
Aluminum Case
|
CAS20014
|
|
Smoke Tester Kit (Mechanical)
|
OPT20038
|
|
Tempest 100 - Accesories and Spares
|
|
Sulfur Dioxide (SO2) Sensor
|
SEN20069
|
|
Nitrogen Dioxide (NO2) Sensor
|
SEN20071
|
|
Carbon Monoxide (CO) Sensor
|
SEN20075
|
|
Oxygen (O2) Sensor
|
SEN20076
|
|
Nitric Oxide (NO) Sensor
|
SEN20077
|
|
Hydrogen Sulfide (H2S)
|
SEN99016
|
|
Hydrogen Chloride (HCI)
|
SEN99017
|
|
3' Probe
|
PRB20062
|
|
Standard 12" Probe with thermocouple
(max 1400F)
|
PRB20063
|
|
High Temperature Probe (max 2000F)
|
PRB20061
|
|
Flexible 6' probe extensions lead
|
TUB20082
|
|
Flexible 12' probe extensions lead
|
TUB20083
|
|
Soft Carrying Case
|
CAS20013
|
|
Aluminum Carry Case
|
CAS20014
|
|
Rechargeable Battery Pack
|
BAT20005
|
|
Battery Charger
|
CHG99007
|
|
Car Charger Lead
|
CHG99002
|
|
Filter Bowl
|
MOL20037
|
|
Filter Bowl Sealing 'O' Ring
|
ORG20052
|
|
Filter Bowl Inner Disc
|
MOL20034
|
|
Filter Bowl Inner Disc Gasket
|
GAS99005
|
|
Filter Bowl Drain Plug
|
PLG20059
|
|
Coalescing Filter Element
|
FIL20021
|
|
Particulate Filter Element
|
FIL20019
|
|
Printer Door Hinge
|
MOL20036
|
|
Printer Paper Roll
|
PAP20053
|
|
Printer Ribbon
|
RIB20068
|
|
6Volt Electric Pump
|
PMP99001
|
|
Smoke Tester Color Chart
|
CHT99001
|
|
Smoke Tester Filter Paper
|
FIL99003
|
|
100 Printer cover
|
MOL20033
|
|
|
|